MOBOTIX D12
CentraleRoccapietra General Event Settings
Activity
Value
Explanation
Arming
Enable
Off
SI Open (high)
SI Closed (low)
CS1
CS2
CSL
From Master
Slave Mode
Arming
:
Arming for Recording, Actions and Messaging:
Enable
: activate all.
Off
: deactivate all.
SI
: arming controlled by signal input.
CS
: arming controlled by custom signal as defined below.
From Master
: copies Main Event Arming state from master camera.
Slave Mode
: full arming slave mode.
Note:
Configuring arming sources as
From Master
or
Slave Mode
requires you to properly configure and enable
Master/Slave
below.
Camera operates in full
Arming Slave Mode!
Arming controls for
Recording
,
Actions
and
Messaging/Messaging 2
are implicitly set to
From Master
.
(no time table)
Weekdays_Mo-Fr
Weekend_Sa-So
Opening_Times
Closing_Times
MyCustomTimes
Time Table Profile
:
Time table profile for time-controlled arming. (
Time Tables
)
Custom Signals
Value
Explanation
Custom Signal 1 (CS1)
Off
Signal Input
Time Table
From Master
Source
:
Specify how to generate custom signal
CS1
.
Off
: set to
false
.
Signal Input
: derive from signal input.
Time Table
: derive from time table.
From Master
: copy
CS1
from the master camera.
Signal Input 1
Signal Input 2
Signal Input 3
Signal Input
:
Select one of the available signal inputs to use as source to
CS1
.
Open (high)
Closed (low)
Signal Input State
:
Specify which signal input state switches
CS1
to
true
.
Weekdays_Mo-Fr
Weekend_Sa-So
Opening_Times
Closing_Times
MyCustomTimes
Time Table
:
Select the time table to use as input to
CS1
.
Custom Signal 2 (CS2)
Off
Signal Input
Time Table
From Master
Source
:
Specify how to generate custom signal
CS2
.
Off
: set to
false
.
Signal Input
: derive from signal input.
Time Table
: derive from time table.
From Master
: copy
CS2
from the master camera.
Signal Input 1
Signal Input 2
Signal Input 3
Signal Input
:
Select one of the available signal inputs to use as source to
CS2
.
Open (high)
Closed (low)
Signal Input State
:
Specify which signal input state switches
CS2
to
true
.
Weekdays_Mo-Fr
Weekend_Sa-So
Opening_Times
Closing_Times
MyCustomTimes
Time Table
:
Select the time table to use as input to
CS2
.
Logically Combined Signal (CSL)
Off
CS1 and CS2
CS1 or CS2
From Master
Source
:
Specify how to logically combine
CS1
and
CS2
in order to produce
CSL
.
And, Or
: available logical combinations.
From Master
: copy
CSL
from the master camera.
Note:
Configuring arming sources as
From Master
or
Slave Mode
requires you to properly configure and enable
Master/Slave
below.
Master/Slave
Value
Explanation
Master/Slave
Enable Master/Slave
:
Specify whether or not this camera supports the processing of signals imported from a master camera and whether or not slave cameras are allowed to log in and to fetch local camera signals.
Master Camera
:
Camera to fetch remote signals from. Only relevant if you specified
From Master
at least once as source to arming controls (camera main arming, recording, actions, messaging) or to custom signals (
CS1
,
CS2
,
CSL
).
Replication Protocol Port
:
IP port used by the network protocol that replicates master camera signals among a set of slave cameras.
Slave Information
Currently mastering no slave cameras.
Update Slave Information
(discards unset changes to this page)
General Settings
Value
Explanation
Event LED Setup
Don't flash LEDs
Flash on any event
Flash on recorded events
Flashing LEDs
:
Controls LED flashing.
Set LEDs in
LED Setup
to
Event
for this feature.
Don't blink
Blink, if armed
Blink, if not armed
Blink, if Recording is armed
Blink, if Recording is not armed
Blink on recording
Blink during Recording dead time
Blink, if Actions is armed
Blink, if Actions is not armed
Blink, if Messaging is armed
Blink, if Messaging is not armed
Blink, if Messaging 2 is armed
Blink, if Messaging 2 is not armed
Blinking LEDs
:
Controls LED blinking.
Set LEDs in
LED Setup
to
Event
for this feature.
Arming Delay
0 s
5 s
10 s
15 s
20 s
25 s
30 s
45 s
60 s
75 s
90 s
Arming Delay
:
Delay of arming by signal input in seconds.
0 s
5 s
10 s
15 s
20 s
25 s
30 s
45 s
60 s
75 s
90 s
Disarming Delay
:
Delay for disarming by signal input in seconds.