MOBOTIX D12
CentraleRoccapietra Event Filter
General Settings
Value
Explanation
Event Filter Dead Time
Event Filter Dead Time
:
Event timeout [0..3600 s] while detection is suspended.
Event Filter
Value
Explanation
Event Counter (EC)
Event Counter Enable
:
If activated, actions will be triggered by the event counter. The event counter counts
all
events selected in the
Event Selection
box.
Individual Events
controls if only the event counter is allowed to trigger actions or if individual events may also trigger actions.
(PI - PIR Detector)
VM - Video Motion
(VM2 - Video Motion 2)
(MI - Microphone)
(SI - Signal Input)
(SI2 - Signal Input 2)
(SI3 - Signal Input 3)
(SI4 - Signal Input 4)
(PE - Periodic Event)
(TT - Time Task)
UC - User Click
(BT - Button)
(BR - Button Right)
(BL - Button Left)
(RC - IP Receive)
(CI - Serial COM In)
(TP - Temperature)
(IL - Illumination)
(IL2 - Illumination 2)
(RD - Random Event)
(RB - Recording Begin)
(RE - Recording End)
(RT - Recording Terminate)
(RH - Recording History)
Events to Count
:
Select the events for this filter.
Use [Ctrl]-Click to select more than one event.
Events in brackets need to be
activated
first.
Ignore events
Use events
Individual Events
:
ignore events
: actions are only triggered by the event counter.
use events
: actions are triggered by the event counter
and
by individual events that have been selected as
Counting Events
.
Counting Period
:
Sliding measurement window [1..3600 s]
Event Count
:
Events to count within window [1..3600 events]
More/equal
Less
Condition
:
True if number of events is
Less
or
More/equal
within Counting Period.
First
Every
Start Action
:
Every
: trigger every second if condition is true
First
: trigger only the first time condition is true